Oil Seal Dust Lip: What a Second Lip Changes on the Drawing

An oil seal dust lip is the second lip on the air side, called a protection lip in ISO 6194-1 Figure 2 b). No clause tolerances it, so the drawing has to.

Oil Seal Dust Lip: What a Second Lip Changes on the Drawing

An oil seal dust lip is the second lip on the air side, called a protection lip in ISO 6194-1 Figure 2 b). No clause tolerances it, so the drawing has to.


Short answer

An oil seal dust lip is a short second lip moulded on the air side of a rotary shaft seal. It runs on the same shaft surface as the sealing lip. No spring sits behind it. ISO 6194-1:2007 calls it a protection lip and draws it in Figure 2 b), one of only two lip arrangements the standard illustrates at all. Its job is to keep abrasive material away from the sealing contact. It carries no pressure rating. No part of ISO 6194 gives any of its dimensions a tolerance. Fitting one moves three entries on a purchase drawing. Width is the first, since footnote a to Table 1 permits b to grow while clause 9.1 bands the width tolerance by b. Depth is the second, because clause 8.1.3 ties the housing bore to b. Speed is the third. Every extra contacting lip adds friction heat. Published ceilings for a contacting dust lip sit near 8 m/s.

Three names for the same piece of rubber

Read the parts of ISO 6194 in order and the second lip changes its name as you go. Clause 5.2 of ISO 6194-1:2007 illustrates two arrangements: a single lip in Figure 2 a); a single lip with protection lip in Figure 2 b). Vocabulary takes the same view. ISO 6194-2 defines the protection lip. Three further entries cover its air side; its fluid side; its diameter in the free state. ISO 6194-5:2008 gives the optional protection lip its own inspection zone in clause 4.7. Performance testing went its own way. Clause 4.3 f) of the withdrawn ISO 6194-4:1999 asked testers to record a minor lip diameter, where applicable.

Trade catalogues mostly write dust lip. Quotations saying protection lip and drawings saying dust lip usually describe the same feature. Settling the wording before a first article inspection costs less than settling it afterwards.

Clause 4 lists eight symbols. None of them is this lip

ISO 6194-1:2007 clause 4 opens the dimensional part with eight symbols. There is a for housing-bore depth; d for the nominal inside diameter of the inner case; b for nominal seal width; c for housing chamfer length. D1 covers the shaft. Letter dm marks the minor diameter at the shaft lead-in chamfer. D2 covers the housing bore together with the seal outside diameter. Radius r closes the list.

Everything the standard tolerances further on has a letter here. Letters stop before the protection lip.

That silence runs to the end of the document. Clause 9.1 gives the width tolerance. Under clause 9.2 the outside-diameter tolerance arrives with its roundness. Clause 7.2 holds the shaft to h11. Clause 7.3 sets the contact surface at Ra 0.2 µm to 0.5 µm with a minimum of 30 HRC. Not one of those clauses reaches the second lip. Its clause 5.2 closes with a sentence that settles where the feature lives: the design of the sealing lip should be agreed between the manufacturer and purchaser.

So the position is awkward in a particular way. ISO 6194-2 names a protection lip diameter. No part of ISO 6194 tolerances it. Any limit on that diameter is a commercial agreement written into your own drawing. Purchase lines reading "with dust lip" carry no number at all.

The 10 mm step moves two tables at once

Second lips need axial room. Footnote a under Table 1 of ISO 6194-1:2007 allows for exactly that. It states that b may be increased to permit the use of more complex seal configurations. Width then stops being a free choice. Two later tables step at b = 10 mm.

Nominal width b Width tolerance, clause 9.1 Table 4 Housing bore depth a, clause 8.1.3 Table 3
b ≤ 10 mm ±0.3 mm b + 1.2 mm
10 mm < b ≤ 14 mm ±0.4 mm b + 1.5 mm
14 mm < b ≤ 18 mm ±0.5 mm b + 1.5 mm
18 mm < b ≤ 25 mm ±0.6 mm b + 1.5 mm

Take a size straight out of Table 1: 65 x 90 x 10. At b = 10 mm the width tolerance is ±0.3 mm. The housing bore has to be 11.2 mm deep. Add a protection lip and the maker takes the footnote up to b = 12 mm. The width tolerance widens to ±0.4 mm. Bore depth now has to reach 13.5 mm. One feature has cost 2.3 mm of housing depth and loosened the width band by 0.1 mm. Cartons rejected for arriving 2 mm wider than the catalogue number may be correct. Housings can be the part that is wrong.

Heat and the speed ceiling that never reaches the data sheet

Every extra contacting lip is another friction source on the same shaft. One elastomer seal maker's technical manual puts the over-temperature at the sealing edge above 20 °C when a dust lip is fitted. Its section on ignition hazards goes further. It records that a standard seal with a dust lip in contact with the shaft can transiently reach shaft surface temperatures above 120 °C, depending on circumferential speed. Tribology work published in 2024 measured the same effect on a friction torque rig and supplied the mechanism. When the protection lip contacts the shaft, a vacuum can form in the cavity between the two lips. Contact pressure rises. Unvented cavities produced both higher torque and higher contact temperature.

Two designs remove the penalty rather than pay it. One bearing maker's catalogue describes an auxiliary lip built with zero lip-to-shaft interference. Its purpose is to avoid added friction; heat falls away with it. Elsewhere, one modification programme offers a shortened dust lip with no overlap at all above 15 m/s.

Guidance on this point carries hard numbers. Up to 8 m/s a dust lip may run in contact with the shaft. Above 8 m/s the same sources call for a vented dust lip so the cavity cannot pull the lips onto the shaft. Above 15 m/s they call for a shortened lip that clears the shaft. Friction is not added; larger particles still get turned back.

Circumferential speed Arrangement the guidance calls for Reason
Up to 8 m/s Contacting dust lip, cavity greased before fitting Exclusion works, and the heat can be carried away
Above 8 m/s Vented dust lip The cavity cannot pull a vacuum on the shaft
Above 15 m/s Shortened lip with no overlap to the shaft No added friction; coarse particles only

Circumferential speed is not rotational speed. On a large shaft the two part company quickly. Conversion runs v = π·d·n / 60 000. Here d is in mm; n is in r/min.

Shaft diameter d r/min at 8 m/s r/min at 15 m/s
20 mm 7 639 14 324
50 mm 3 056 5 730
80 mm 1 910 3 581
100 mm 1 528 2 865
150 mm 1 019 1 910
200 mm 764 1 432

At 1 500 r/min a 100 mm shaft sits at 7.85 m/s, just inside the contacting window. The same shaft at 1 600 r/min reaches 8.38 m/s and falls outside it. Nothing about the seal changed. Duty alone moved, which is why purchase orders naming a double-lip profile while naming neither shaft diameter nor speed have specified nothing that anyone can test.

Grease in the cavity: too little wears the lip, too much looks like a leak

Dust lips run without oil on the air side. Springs do not sit behind them. They depend on grease packed into the cavity before assembly. One technical manual puts the fill at about 40 % of the cavity volume. Grease there lubricates the dust lip; it also guards the shaft against corrosion. One bearing maker's catalogue asks for the cavity to be filled with a grease compatible with the service lubricant. Figures for quantity are not offered.

Both directions of error leave a signature. Too little grease leaves the protection lip running dry, which produces the damage it was fitted to prevent. Too much forces the surplus out of the cavity as the assembly warms. Technical literature names that apparent leakage. Elsewhere the same event is called false leakage. End customers read the escaping medium as a leaking seal. Claims opened on seals that weep clean grease during their first running hours often trace back to a filling instruction nobody wrote down.

Figure Where it comes from What it decides
8 m/s Seal maker guidance on dust lip contact Whether the second lip may touch the shaft
15 m/s Same guidance, shortened lip variant Whether any overlap to the shaft remains
20 °C Technical manual, over-temperature with a dust lip How much hotter the sealing edge runs
120 °C Same manual, section on ignition hazards Transient shaft surface temperature
40 % Technical manual, cavity grease fill Whether the lip runs dry or weeps grease

Where a second lip earns its keep

Contaminated duty is the argument for it. Construction machinery; agricultural drives; mining plant. Each carries abrasive material to the shaft outside the housing. Once grit reaches a wet shaft surface it migrates toward the sealing edge and turns into lapping compound. Correctly arranged, the second lip intercepts it first.

Arrangement has to be right for that to happen. The protection lip belongs on the air side. Assembled the wrong way round, a double-lip profile puts the primary lip outward where it retains nothing. Second lips also double the number of contact bands on the shaft. Clause 7.3 sets Ra 0.2 µm to 0.5 µm and 30 HRC for the seal contact surface. Two-lip seals need that finish across both bands. One band sits under the spring; the other does not. Retrofit a double lip so that its second band lands on a worn or corroded stretch of shaft and it will leak. Blame then lands on the new part.

Severe contamination has other answers. Technical literature points at four of them: two seals fitted in line; an axially aligned dust lip working against a slinger to form a labyrinth at higher speeds; cassette constructions for the heaviest dirt loads; a non-woven excluder whose open structure stops the lips being drawn onto the shaft at high peripheral speed. Each of those leaves the primary seal as a single-lip part, with the tolerance band it was designed around.

What goods-in should measure

ISO 6194-5:2008 sorts surface imperfections into five zones and gives each a name. Optional protection lips form the zone in clause 4.7, with four names: tear; cut or nick; non-fill; flash. Size limits are attached to none of them, in any zone.

Inspectors reach for numbers that belong somewhere else. Table 1 of ISO 6194-5 sizes a sealing lip critical area with two dimensions. They are called x and y. Three shaft bands set the values. Up to 50 mm the pair is 0.6 mm and 1.2 mm. From 50 mm to 120 mm it is 0.8 mm and 1.5 mm. Beyond 120 mm the figures are 1.0 mm and 2.0 mm. Those values come from clause 4.1, which is written about the sealing lip. Any procedure rejecting a protection lip for a nick at 0.9 mm on a 40 mm shaft is applying a limit written for a different part of the seal.

Measurement without judgement is what the performance test part gives the second lip. ISO 6194-4 clause 4.3 asks for the protection lip diameter to be recorded before the rig runs. It wants the figure twice: with the sealing lip spring fitted; then without it. Clause 5.5 asks for it again afterwards. Acceptance in that test rests on leakage. Measured twice, judged never: that is where the second lip stands.

What to put on the drawing

  • Lip arrangement. Name Figure 2 a) or Figure 2 b) of ISO 6194-1:2007, then use one term across the document set.
  • Nominal width b as the figure you actually need, with the tolerance band from Table 4 stated. Catalogue numbers do not carry it.
  • Housing bore depth from Table 3, checked against the width you have just written.
  • Protection lip diameter with a tolerance of your own. No part of ISO 6194 gives one.
  • Circumferential speed at the shaft diameter. Rotational speed alone says nothing.
  • Venting of the cavity, stated explicitly. Grease fill with a quantity attached.
  • Roughness and hardness across the full contact length, both bands.

Metal-cased seals photographed from the air side. The outboard lip is the protection lip, and it is the one with no spring behind it.

Questions buyers ask about the second lip

Does a dust lip make the seal pressure rated?

No. Clause 6.1 of ISO 6194-1:2007 keeps these seals at 0 kPa to 30 kPa above atmospheric and refers anything higher back to the seal manufacturer. Dust lips sit on the air side and exclude dirt. Pressure capability comes from lip geometry; case stiffness; any support ring. Dust lips provide none of them.

Can a single lip be swapped for a double lip in the same housing?

Only after checking depth. If the second lip takes b past 10 mm, Table 3 moves the required bore depth from b + 1.2 mm to b + 1.5 mm. On the 65 x 90 example that is 2.3 mm. That will not fit a housing machined for the narrower part.

Why did the seal leak in its first week and then stop?

Check the grease fill before checking the lip. Apparent leakage from an overfilled cavity is a temporary condition in the literature. It stops once the surplus has escaped. Leakage continuing past the first running hours is a different fault.

Is the second lip inspected to the same rule as the first?

It has its own zone. Under clause 4.7 of ISO 6194-5 four imperfections are named for the optional protection lip. Size limits do not come with them. Those x and y values come from clause 4.1; they belong to the sealing lip.

What should a test report carry for a double-lip seal?

Declared values under ISO 6194-4 clause 4.2, tied to a batch number. Add the pre-test diameters from clause 4.3; add the post-test ones from clause 5.5. Ask for the protection lip diameter in particular. Clause 4.3 asks for it anyway, yet few reports print it.

Rubber-covered and cassette constructions. Width and bore depth decide whether a double-lip part fits a housing machined for a single-lip one.

Putting it back on your own drawing

Least specified of all is the second lip, on a part otherwise dimensioned to the millimetre. Eight symbols in clause 4 of ISO 6194-1:2007 cover the shaft; the bore; the width; the chamfer; the corner radius. No symbol is assigned to it. Tolerance is absent. Acceptance numbers do not appear anywhere in the series. Clause 5.2 states that its design is a matter for agreement. Write that agreement down. Arrangement; width; depth; lip diameter with a tolerance of your own; speed; grease. Six lines. They cost less than the argument they prevent.

Standards referenced: ISO 6194-1:2007 (clause 4, 5.1, 5.2, 6.1, 7.2, 7.3, 8.1.3, 9.1, 9.2, Table 1, Table 3, Table 4), ISO 6194-2 (vocabulary), ISO 6194-3 (storage, handling and installation), ISO 6194-4 (clause 4.2, 4.3, 5.5, 5.7), ISO 6194-5:2008 (clause 4.1, 4.7, Table 1), ISO 16589 (thermoplastic sealing elements), ISO 286-2 (h11, H8), ISO 5598 (fluid power vocabulary), ISO 48, ISO 2781, ISO 815, ISO 1817, ISO 2921.

Need help specifying a seal?

Use these checks to prepare your enquiry. Final suitability depends on the specific design and operating conditions.

Check dimensions and design

Provide the shaft diameter, housing bore and seal width in mm. Include the part marking, lip profile or a dimensioned drawing if available.

Browse product specifications

Describe operating conditions

Share the fluid or medium, operating temperature, pressure and shaft speed. Confirm the material grade against the application.

Read the materials guide

Verify a replacement

Provide the original part number and photos. Similar dimensions alone do not confirm interchangeability; compare the design and material.

Check part references

Ask for selection assistance

View interactive page